EPA-RCA: 8321B:  Nonvolatiles by HPLC-MS

  • Summary
  • Analytes
  • Revision
  • Data and Sites
Official Method Name
Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TSP-MS) or Ultraviolet (UV) Detection
Current Revision
Rev. 2, Feb. 2007
Media
VARIOUS
Instrumentation
High Performance Liquid Chromatography with Mass Spectrometry
Method Subcategory
Organic
Method Source
  EPA-RCA
Citation
  SW-846 Online: Test Methods for Evaluating Solid Waste, Physical/Chemical Methods
Brief Method Summary
This method provides reversed-phase high-performance liquid chromatographic (RP/HPLC) and thermospray (TS) mass spectrometric (MS) conditions and ultraviolet (UV) conditions for the detection of the target analytes.

SW-846 is not intended to be an analytical training manual. Therefore, method procedures are written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology.

In addition, SW-846 methods, with the exception of required method use for the analysis of method-defined parameters, are intended to be guidance methods which contain general information on how to perform an analytical procedure or technique which a laboratory can use as a basic starting point for generating its own detailed Standard Operating Procedure (SOP), either for its own general use or for a specific project application. The performance data included in this method are for guidance purposes only, and are not intended to be and must not be used as absolute QC acceptance criteria for purposes of laboratory accreditation.

This method provides reversed-phase high performance liquid chromatographic (RP-HPLC), thermospray (TSP) mass spectrometric (MS), and ultraviolet (UV) conditions for detection of the target analytes. Sample extracts can be analyzed by direct injection into the thermospray or onto a liquid chromatographic -thermospray interface. A gradient elution program is used to separate the compounds. Primary analysis may be performed by UV detection; however, positive results should be confirmed by TSP-MS. Quantitative analysis may be performed by either TSP-MS or UV detection, using either an external or internal standard approach. TSP-MS detection may be performed in either a negative ionization (discharge electrode) mode or a positive ionization mode, with a single quadrupole mass spectrometer. The use of MS-MS techniques is an option.
Scope and Application
This method covers the use of high-performance liquid chromatography (HPLC), coupled with both thermospray-mass spectrometry (TS-MS) and an ultraviolet (UV) detector, for the determination of a variety of solvent-extractable nonvolatile compounds, including dyes, organophosphorus compounds, phenoxyacid herbicides, and carbamates.
Applicable Concentration Range
Interferences
Solvents, reagents, glassware, and other sample processing hardware may yield discrete artifacts or elevated baselines, or both, causing misinterpretation of chromatograms or spectra. All of these materials must be demonstrated to be free from interferences under the conditions of the analysis by analyzing method blanks. Specific selection of reagents and purification of solvents by distillation in all-glass systems may be necessary. Refer to each method to be used for specific guidance on quality control procedures and to Chapter Four for general guidance on the cleaning of glassware.

See section 4 of the method for more information on interferences.
Quality Control Requirements
See section 9.0 of the method for a complete discussion of Quality Control.
Sample Handling
Maximum Holding Time
Relative Cost
Less than $50
Sample Preparation Methods