DOE EML: U-02-RC: Isotopic Uranium in Biological and Environmental Materials
Official Method Name
|
EPA Approved- ISOTOPIC URANIUM IN BIOLOGICAL AND ENVIRONMENTAL MATERIALS |
---|---|
Current Revision
| EML Procedures Manual HASL-300, Volume 1, 28th Ed.(1997) |
Media
|
VARIOUS |
Instrumentation
|
Alpha Spectrometer/Counter |
Method Subcategory
|
Radiochemical |
Method Source
|
|
Citation
|
|
Brief Method Summary
|
Uranium from acid leached, dry-ashed and wet-ashed materials is equilibrated with 232U tracer, and is isolated by anion exchange chromatography. The separated U isotopes are microprecipitated for alpha spectrometry (Hindman, 1983; Sill and Williams, 1981; Welford et al., 1960). |
Scope and Application
|
This procedure has been used to analyze soft tissue, vegetation, water, and air filter samples to determine isotopic uranium. |
Applicable Concentration Range
|
None given. |
Interferences
|
None given. |
Quality Control Requirements
|
Reagent blanks must be analyzed with each set batch of samples to correct the U results. |
Sample Handling
|
None given. |
Maximum Holding Time
|
None given. |
Relative Cost
|
$51 to $200 |
Sample Preparation Methods
|